barrel vaults -

Cintralux PC 10 Aluflex

Cintralux aluminium barrel vault 10 mm on sloping curb

Homepage banner

Barrel vault for narrow spans

  • For unheated buildings
  • As a canopy
  • Budget-friendly
  • Suitable for renovation projects (existing bevelled curb)
Download brochure

The Cintralux PC 10 Aluflex barrel vault is made using extruded aluminium profiles and sturdy plastic glazing. This glazing consists of a 4-walled 10 mm polycarbonate sheet and is produced as a fully finished unit. This barrel vault is ideally suited to non-heated and non-EPB-compliant buildings. Are you also looking for lightweight construction? Then this barrel vault is the ideal choice.

The polycarbonate sheets have a co-extruded UV protection layer on the upper surface. This maintains optimal light transmission. For an opal heat-resistant version, a special opal PC cavity plate is used as the outer panel, providing high reflection for infrared rays with a heat-resistant effect as a result.

You can also extend this barrel vault using Broof (t1). This involves installing a fire-resistant polyester sheet under the polycarbonate sheet of the barrel vault.

Avoid falls during installation and maintenance? Choose optional galvanised 12oo joule anti-drop nets.

Specifications & documents

Combine this barrel vault with
smoke and heat extraction

The Cintralux PC 10 Aluflex barrel vault can be extended using our Cintramax CE smoke and heat extraction system. This opening section, which can be built in with widths from 1.5 to 4 metres, consists of two galvanised scissor systems mounted on the inside of the curb. The Cintramax CE can also be used for comfort ventilation.

Read more
DSC08872 HDR 2

Specifications and documents

Consult all documentation and technical information on this barrel vault here so that you can make the right choice for your project.

Specifications

Application

Non EPB-compliant buildings

Buildings in Flanders have to meet certain standards on 'Energy Performance and Indoor Climate' (EPB). The requirements set depend on the use of the building, the nature of the works and the year of the licence application. More info can be found here.

Min.-max. overall/external dimensions

1,12 - 4.12

Utp [W/m².K]

2,5

Urc [W/m².K] (for light size 3x30 m)

2,76

Url=Uw [W/m².K] (for light size 3x30 m)

3,49

Curb form

Sloping curb

SHEV

Cintramax CE 24V

Natural ventilation

Cintrair & Cintramax

Broof (t1) option

Yes

Option 1200J

Yes

Safety first Quote